PART NUMBER:48-2731 |
|||||
|
|||||
| INDICATED USE: General purpose survey,
gross counting COMPATIBLE DETECTORS: G-M, proportional, scintillation DET1/DET2: A locking toggle switch to allow for quick change between two detector setups CONNECTOR: Series "C" (others available on request) AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet) ALERT/ALARM: Indicated by enunciator on display and audible tone DISPLAY: 4 digit LCD display with 0.5"(1.3cm) high digits, separate enunciators for display units, alert, alarm, low battery, detector overload, counting overflow, and scaler counting BACKLIGHT: Push-button to activate RATEMETER: Can display in R/hr, Sv/hr, cpm, or cps when control switch is in RATEMETER position DISPLAY RANGE: Auto ranging from 0.0 microR/hr - 9999 R/hr; 0.000 microSv/hr - 9999 Sv/hr; 0 cpm - 999k cpm; or 0 cps - 100k cps LINEARITY: Reading within plus or minus 10% of true value with detector connected SCALER: Activated by push-button in handle (count time adjustable from 1 - 9999 seconds in 1 second intervals) CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided) HIGH VOLTAGE: Two independent controls, each adjustable from 200 - 2500 volts DISCRIMINATOR: Two independent controls, each adjustable from 2 - 100 mV OVERLOAD: Indicated by OVERLOAD on display (adjustable depending on detector selected) RESET: Push-button to zero display, acknowledge and/or reset alarm POWER: 2 each "D" cell batteries (housed in sealed compartment that is externally accessible) BATTERY LIFE: Typically 200 hours with alkaline batteries (24 hours when low battery is first indicated on display) CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C) May be certified for operation from -40° F(-40° C) to 150° F(65° C) SIZE: 6.5"(16.5cm)H X 3.5"(8.9cm)W X 8.5"(21.6cm)L WEIGHT: 3.5 lbs (1.6kg) including batteries The following parameters are adjusted by removable switchboard. Once initial setup and calibration have been completed the switchboard can be removed without affecting normal operation of the instrument (Model 2241-2 may be ordered without switchboard) BACKLIGHT "ON" TIME: 5, 30, 60, 90, 180, or 240 seconds for the backlight to stay "ON" when activated. SET MINIMUM DISPLAY: Allows lower limit of auto-ranging display to be fixed. For example, display can be set to not show values less than 1 R/hr. RS-232 DATA DUMP MODE: Enables or disables dump mode to RS-232 port. When enabled data will be dumped every 2 seconds RS-232 DETECTOR SETUP MODE: Allows for detector parameters to be input by RS- 232 port BAUD RATE: 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps. DEAD TIME: Adjustable from 0 - 9999 seconds CALIBRATION CONSTANT: Adjustable from 0.001 - 280 X 109 counts/display unit DISPLAY UNITS: Can read in R/hr, Sv/hr, cpm, or cps TIME BASE: Can read in seconds or minutes AUDIO DIVIDE: 1, 10, 100, or 1000 events-per-click RESPONSE: Fixed: FAST response time adjustable from approximately 2 - 50 seconds. SLOW response is 5 times fast setting Variable: Dependent on number of counts present. Typical times FAST - 4 - 25 seconds, SLOW - 4-60 seconds (All times stated from 10% to 90% of final reading) RATEMETER ALERT/ALARM: Set at any point corresponding to pre-selected ratemeter range SCALER ALARM: Adjustable from 1 - 999999 counts SCALER COUNT TIME: Adjustable from 1 - 9999 seconds |
|||||
|
|
|||||
| This survey meter is compatible with most Ludlum probes. | |||||
|
|
|||||
|
Model 2241 Series Digital Display |
|||||
|
|
|||||
|
|
|||||
|
|||||
| Emergency Response | Nuclear Medicine | Radiation Therapy | |
| HOME | |||
| Calibration Services Available | |||
Atlantic Nuclear / tel 781-878-9118 / fax 781 878 3378 / email: anc@att.net 100 Weymouth St. STE E-1 / Rockland, MA 02370 |
|||
|