Model 12 Ratemeter |
- 4 Ranges
- Adjustable High Voltage
- Adjustable Threshold
- Utilizes G-M, Scintillation, or
Proportional Detectors
- Built In Audio with ON/OFF Switch
- Total Range from 0 - 500,000 cpm
- Splash Proof
|
PART NUMBER:48-1609

|
COMPATIBLE DETECTORS: G-M, proportional,
scintillation
METER DIAL: 0 - 500 cpm, 0 - 2.5 kV, BAT TEST (others available
)
MULTIPLIERS: X1, X10, X100, X1000
LINEARITY: Reading within plus or minus 10% of true value with
detector connected
CONNECTOR: Series "C" (others available )
AUDIO: Built in unimorph speaker with ON/OFF switch (greater
than 60 dB at 2 feet )
CALIBRATION CONTROLS: Accessible from front of instrument (protective
cover provided )
HIGH VOLTAGE: Adjustable from 200 - 2500 volts (can be read on
meter )
DISCRIMINATOR: Adjustable from 1 - 100 mV
RESPONSE: Toggle switch for FAST (4 seconds) or SLOW (22 seconds)
from 10% to 90% of final reading
RESET: Push-button to zero meter
POWER: 2 each "D" cell batteries (housed in sealed compartment
that is externally accessible )
BATTERY LIFE: Typically 2000 hours with alkaline batteries (battery
condition can be checked on meter )
METER: 2.5" (6.4 cm) arc, 1 mA analog type
CONSTRUCTION: Cast and drawn aluminum with beige powdercoat
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 6.5" (16.5 cm)H X 3.5" (8.9 cm)W X 8.5" (21.6 cm)L
WEIGHT: 3.5 lbs (1.6 kg) including batteries
Manual |
|
|
| |
| *For Mylar window scintillators it is strongly
suggested that the optional overload indicator be used on the Model 12
Ratemeter to better determine the presence of a light leak. |
|
|
|
Common Meter Dials |
|
|
|
|
|
202-356
0 - 500 cpm; 0-2.5 kV
For Any Detector |
202-354
0-10 cps; 0-2.5 kV
For Any Detector |
202-618
0-660 cpm; 0-0.2 mR/hr
For Model 44-9; 44-9-18;
44-40; 44-88; 44-89; 44-94 |
|
|
|
|
|
|
|
202-428
0-5 mR/hr
For Model 44-2 |
202-645
0-5 mR/hr; 0-800 cpm
For Model 44-2 and 44-9 |
|
|
|
|
Suggested detectors are listed below and are not included
with the survey meter price. An additional charge will be added for
each detector ordered.
|
|
|
| *For Mylar window scintillators it is strongly
suggested that the optional overload indicator be used on the Model 12
Ratemeter to better determine the presence of a light leak. |
|
|
|
Accessories |
Replacement Parts
|
|
Check Source
Source Holder
Overload Indicator
Scaler Option
Shoulder Strap
Headset
Standard Carrying Case
Air and Water Tight Carrying Case |
Cables
Meter Bezel
Meter Movement
Handle
Probe Clip |
|
|
|
| |
|