Model 14C Survey Meter

This meter is designed to meet nuclear medicine requirements. It is used in universities, power plants and regulatory facilities. This five range survey meter consists of one internal GM detector for gamma detection from 0-2000 mR/hr. It can be used with one or more external GM or scintillation detectors for alpha, beta, or gamma detection up to 0-200 mR/hr. Standard scale is 0-2 mR/hr with five counting ranges: x0.1, x1, x10, x100, and x1000. (Dual scale cpm & mR/hr on request). Two “D” cells provide over 200 hours of operation. The Model 14C is supplied as shown with built-in speaker. 
COMPATIBLE DETECTORS: G-M, scintillation
METER DIAL:Typically 0 - 2 mR/hr and cpm, BAT TEST (others available )
MULTIPLIERS: X0.1, X1, X10, X100, X1000
LINEARITY: Reading within plus or minus 10% of true value with detector connected
CONNECTOR: Series "C" (others available )
INTERNAL DETECTOR: Energy compensated G-M (used with X1000 scale only)
ENERGY RESPONSE: Within plus or minus 15% of true value between 60 keV - 3 MeV (internal detector only )
THRESHOLD: 30 mV plus or minus 10 mV
AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet )
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided )
HIGH VOLTAGE:900 volts
THRESHOLD: 30 mV plus or minus 10 mV
RESPONSE: Toggle switch for FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading
RESET: Push-button to zero meter
POWER: 2 each "D" cell batteries (housed in sealed compartment that is externally accessible )
BATTERY LIFE: Typically greater than 1000 hrs.(battery condition can be checked on meter )
METER: 2.5" (6.4 cm) arc, 1 mA analog type
CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 6.5" (16.5 cm)H X 3.5" (8.9 cm)W X 8.5" (21.6 cm)L
WEIGHT: 3.5 lbs (1.6 kg) including batteries

Note that the Model 14C houses an internal energy-compensated G-M detector with limitations listed in the description. External suggested detectors are listed below and are not included with the survey meter price. An additional charge will be added for each detector ordered.  

For
Alpha
Detection

For
Beta
Detection

For
Gamma
Detection

For Alpha/beta/gamma Detection

Model 44-7
Model 44-9
Model 44-88
Model 44-89
Model 44-94

Model 44-6
Model 44-7
Model 44-9
Model 44-38
Model 44-88
Model 44-89
Model 44-94

Model 44-2
Model 44-3
Model 44-6
Model 44-7
Model 44-9
Model 44-38

Model 44-7
Model 44-9
Model 44-88
Model 44-89
Model 44-94

Common Meter Dials

 202-859
0 - 5k cpm; 0-2 mR/hr
For Any Detector

 202-608
0-6.6k cpm; 0-2 mR/hr
For Model 44-9; 44-9-18;
44-40; 44-88; 44-89; 44-94

 202-664
0-6.6k cpm; 0-20
mSv/h
For Model 44-9; 44-9-18;
44-40; 44-88; 44-89; 44-94

 


 

202-330
0-4k cpm; 0-2 mR/hr
For Model 44-7
 

 202-676
0-4k cpm; 0-20
mSv/h
For Model 44-7

202-084
0-2 mR/hr
For Model 44-6; 44-38

 


202-379
0-20
mSv/h
For Model 44-6; 44-38

202-241
0-2 mR/hr; 0-2.4k cpm
For Model 44-6; 44-38

202-546
0-20
mSv/h; 0-2.4k cpm
For Model 44-6; 44-38

 

Accessories

Replacement Parts

Check Source
Source Holder
Overload Indicator
Scaler Option
Shoulder Strap
Headset
Standard Carrying Case
Air and Water Tight Carrying Case

Cables
Meter Bezel
Meter Movement
Handle
Probe Clip

 

 Manual        Model 14c Response Curve

 DS 051-014 survey meter  
 DS 051-014-7 survey meter w/ 44-7 probe  
 DS 051-014-9 survey meter w/ 44-9 probe  
 DS 051-014-3/9 survey meter w/ 44-9 and 44-3 probe  
 
Emergency Response Nuclear Medicine Radiation Therapy

SEARCH

HOME
Calibration Services Available

Atlantic Nuclear / tel 800 878 9118 / fax 781 828 1319 / email: anc@att.net

1020 Turnpike St. #9 /Canton, MA 02021