DETECTORS: Model 44-9 Pancake G-M,
Model 44-2 Gamma Scintillator, Model 133-7 High Range Energy Compensated
G-M
CONTROL SWITCH: A 5 position rotating switch to allow for quick
change between four detector setups
CONNECTOR: Series "C" (others available on request)
AUDIO: Built in unimorph speaker with ON/OFF switch (greater
than 60 dB at 2 feet)
ALERT/ALARM: Indicated by enunciator on display and audible tone
DISPLAY: 4 digit LCD display with 0.5"(1.3cm) high digits, separate
enunciators for display units, alert, alarm, low battery, detector
overload, counting overflow, and scaler counting
BACKLIGHT: Push-button to activate
RATEMETER: Can display in R/hr, Sv/hr, cpm, or cps when control
switch is in RATEMETER position
DISPLAY RANGE: Auto ranging from 0.0 microR/hr - 9999 R/hr; 0.000
microSv/hr - 9999 Sv/hr; 0 cpm - 999k cpm; or 0 cps - 100k cps
LINEARITY: Reading within plus or minus 10% of true value with
detector connected
SCALER: Activated by push-button in handle (count time
adjustable from 1 - 9999 seconds in 1 second intervals)
CALIBRATION CONTROLS: Accessible from front of instrument (protective
cover provided)
HIGH VOLTAGE: Four independent controls; each adjustable from 200 -
2500 volts
DISCRIMINATOR: Adjustable from 2 - 100 mV
OVERLOAD: Indicated by OVERLOAD on display (adjustable depending
on detector selected)
RESET: Push-button to zero display, acknowledge and/or reset alarm
POWER: 2 each "D" cell batteries (housed in sealed compartment
that is externally accessible)
BATTERY LIFE: Typically 200 hours with alkaline batteries (low
battery indicated on display)
CONSTRUCTION: Cast and drawn aluminum with beige polyurethane
enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 6.5"(16.5cm)H X 3.5"(8.9cm)W X 8.5"(21.6cm)L
WEIGHT: 3.5 lbs (1.6kg) including batteries
If special calibration requirements are not initially specified,
calibration will be made based on the default settings shown below:
| |
Color Dot:
Probe model:
Units/Timebase:
Rate Alarm:
Rate Alert:
Scaler Alarm:
Scaler count time: |
|
Red
44-9
cpm
50 kcpm
20 kcpm
85000
12 sec. |
Yellow
44-2
R/hr
50 µR/hr
20 µR/hr
85000
12 sec. |
Blue
133-7
R/hr
5 R/hr
2 R/hr
85000
12 sec. |
White
44-9
R/hr
5 mR/hr
2 mR/hr
85000
12 sec. |
|
The following parameters are adjusted by removable switchboard. Once
initial setup and calibration have been completed the switchboard can be
removed without affecting normal operation of the instrument (Model
2241-2 may be ordered without switchboard)
BACKLIGHT "ON" TIME: 5, 30, 60, 90, 180, or 240 seconds for the
backlight to stay "ON" when activated.
SET MINIMUM DISPLAY: Allows lower limit of auto-ranging display to
be fixed. For example, display can be set to not show values less than 1
R/hr.
RS-232 DATA DUMP MODE: Enables or disables dump mode to RS-232
port. When enabled data will be dumped every 2 seconds
RS-232 DETECTOR SETUP MODE: Allows for detector parameters to be
input by RS- 232 port
BAUD RATE: 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps.
DEAD TIME: Adjustable from 0 - 9999 seconds
CALIBRATION CONSTANT: Adjustable from 0.001 - 280 X 109
counts/display unit
DISPLAY UNITS: Can read in R/hr, Sv/hr, cpm, or cps
TIME BASE: Can read in seconds or minutes
AUDIO DIVIDE: 1, 10, 100, or 1000 events-per-click
RESPONSE:
FIXED: FAST response time adjustable from approximately 2 - 50
seconds. SLOW response is 5 times fast setting
VARIABLE: Dependent on number of counts present. Typical times FAST
- 4 - 25 seconds, SLOW - 4-60 seconds
(All times stated from 10% to 90% of final reading)
RATEMETER ALERT/ALARM: Set at any point corresponding to
pre-selected ratemeter range
SCALER ALARM: Adjustable from 1 - 999999 counts
SCALER COUNT TIME: Adjustable from 1 - 9999 seconds |